Brand Name : Yokogawa
Model Number : RC800D
MOQ : 1pcs
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Object : Free chlorine or residual chlorine (total chlorine) in water
Measuring System : Amperometric method (Polarographic method) using rotating electrode
Measuring Range : 0-10 mg/L
Power Supply : 100 to 240 V DC, 50/60 Hz
"Reliable Chlorine monitoring and minimize Chlorine injection"
"Continuous automatic cleaning and achieved less maintenance time"
"Maintenance remotely and reduce maintenance time"
Many of our customers face these challenges - Yokogawa Chlorine Analyzers resolve them.
The RC800D residual chlorine analyzer employs a polarographic system that uses rotating platinum electrodes to provide a continuous online measurement of residual chlorine concentration. It is possible to separate residual chlorine (free chlorine + combined-chlorine) from free chlorine for measurements by appropriate use of reagents.
The RC800D is suitable for various water condition measurements and gives you a stable and high-quality measurement thanks to the rotation electrodes and superior reagent pump.
The RC800D is intended for water distribution measurements at pumping stations, water delivery points, schools, and public facilities.
*Based on a Yokogawa survey in 2019
Water Purification Treatment
Measured Object | Free chlorine or residual chlorine (total chlorine) in water | |
---|---|---|
Measuring System | Amperometric method (Polarographic method) using rotating electrode | |
Measuring Range | 0-10 mg/L | |
Sample Conditions | Temperature | 0 to 50°C (Temperature compensation is effective within 0 to 40°C) |
pH | 3 to 9 | |
Flow Rate | 1 to 4 L/min, for pure water or municipal water application. 5 to 10 L/min, for raw water or sea water application. 10 to 20 L/min, for secondary sewage treatment application. | |
Pressure | 20 to 500 kPa | |
Power Supply | 100 to 240 V DC, 50/60 Hz | |
Digital Communication | Modbus TCP/IP, Modbus RTU | |
Installation | Indoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.) |
Linearity | ±3% of reading or ±0.03 mg/L whichever is greater |
---|---|
Repeatability | ±1% of reading or ±0.01 mg/L whichever is greater |
![]() |
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants Images |